Product Name: | Pressure Reducing Valve | Application: | Water, |
---|---|---|---|
Size: | DN32 ~DN400 | Pressure: | PN10/16/150lbs/JIS10K |
Standard: | DIN / BS / AWWA / JIS | Temperature: | -20~120 C |
Body: | Ductile Iron as per EN 1563 GGG-40 | Disc: | Ductile iron with EPDM |
Stem: | 2Cr13 / SS304 | Diaphragm: | EPDM |
Pipe fitting: | Brass | ||
تسليط الضوء: | pressure sustaining valve,pump control valve,pump control valve |
Pressure Reducing Valve Body/Top Cover: Ductile Iron as per EN 1563 GGG-40
Product Specification
Body/Top Cover: Ductile Iron as per EN 1563 GGG-40;
Piping: Stainless steel 1.4571
Filter casing: Brass
Pilot valve body: Brass;
FBE color: RAL Blue 5002 with min. 250 Microns
Standard
Face to Face in acc. with EN 558-1;
IS 9739 Flange ends on both sides acc. to EN 1092-2;
Testing in acc. to EN 12266-1;
Fusion Bonded Non-toxic Epoxy Powder Coating; NSF 61/WRAS;
Technical requirements:-
Size from DN32 to DN700
Hydraulic valve for controling pressure and flow rate
(with an excess flow pilot and a pressure regulator pilot)
Main characteristics:
• Standard: EN ISO 9635-5:2014 and EN 14267:2004
• Body & bonnet: ductile iron, coated Epoxy 250 μm
• Diaphragm: rubber+reinforced nylon
• Spring: stainless steel
• Screws: stainless steel
• Connecting: flanged ends
• Pressure loss < 0.10 bar (completely open)
• Pressure loss < 0.40 bar (with orifice)
• Pilots: Bronze
• Excess flow pilot: type three-ways differential pressure, spring adjustable on the spot,
material: bronze, in combination with a calibrated orifice disk
(made of stainless steel or plastic) for the differential pressure measurement,
comprising the connecting to the hydraulic valve by PEHD pipes
(DN6-8-12mm according to the DN of the valve)
• Pressure regulator pilot: three-ways,
material: bronze, spring adjustable on the spot,
comprising the connecting to the hydraulic valve by PEHD pipes
(DN6-8-12mm according to the DN of the valve)
Medium: Water
DN | L | D | D1 | D2 | Z-~d | H1 | H | ||||||||
PN10 | PN16 | PN25 | PN10 | PN16 | PN25 | PN10 | PN16 | PN25 | PN10 | PN16 | PN25 | ||||
50 | 203 | 165 | 165 | 165 | 125 | 125 | 125 | 102 | 102 | 99 | 4-~18 | 4-~18 | 4-~18 | 137 | 95 |
65 | 216 | 185 | 185 | 185 | 145 | 145 | 145 | 122 | 122 | 118 | 4-~18 | 4-~18 | 8-~18 | 145 | 97 |
80 | 241 | 200 | 200 | 200 | 160 | 160 | 160 | 133 | 133 | 132 | 8-~18 | 8-~18 | 8-~18 | 178 | 109 |
100 | 292 | 220 | 220 | 235 | 180 | 180 | 190 | 158 | 158 | 156 | 8-~18 | 8-~18 | 8-~18 | 232 | 152 |
125 | 330 | 250 | 250 | 270 | 210 | 210 | 220 | 184 | 184 | 184 | 8-~18 | 8-~18 | 8-~18 | 286 | 152 |
150 | 356 | 285 | 285 | 300 | 240 | 240 | 250 | 212 | 212 | 211 | 8-~18 | 8-~18 | 8-~18 | 318 | 160 |
200 | 495 | 340 | 340 | 360 | 295 | 295 | 310 | 268 | 268 | 274 | 8-~18 | 12-~18 | 12-~18 | 413 | 220 |
250 | 622 | 395 | 405 | 425 | 350 | 355 | 370 | 320 | 320 | 330 | 12-~18 | 12-~18 | 12-~18 | 502 | 250 |
300 | 698 | 445 | 460 | 485 | 400 | 410 | 430 | 370 | 370 | 389 | 12-~18 | 12-~18 | 12-~30 | 600 | 372 |
350 | 787 | 505 | 520 | 550 | 460 | 470 | 490 | 430 | 430 | 448 | 16-~22 | 16-~26 | 16-~33 | 526 | 314 |
400 | 914 | 565 | 580 | 620 | 515 | 525 | 550 | 482 | 482 | 503 | 16-~26 | 16-~30 | 16-~36 | 570 | 340 |
450 | 787 | 565 | 580 | 620 | 515 | 525 | 550 | 482 | 482 | 503 | 16-~26 | 16-~30 | 16-~36 | 677 | 415 |
Main Technical Feature | ||||||||
Nominal Pressure | 1.0MPA | 1.6MPA | 2.5MPA | |||||
Test pressure of the shell | 1.5MPA | 2.4MPA | 3.75MPA | |||||
Sealed test pressure | 1.1MPA | 1.76MPA | 2.75MPA | |||||
Suitable temperature | ≤80℃ | |||||||
Suitable medium | water |
|
Product Specification | ||||||||
The 400X flow control valves is a multifunctional valves that adopts the mode of flow control employed by high-precision pilot valves.
It is suitable for use in water distribution pipes within which the flow and pressure need to be controlled,
and can serve to keep the preset flow constant, restrict excessive flow at a preset value and reduce
the excessively high pressure upstream properly. This valves differs from other conventional throttle
valves, which normally work through reducing the flow area by means of orifice plates or purely
mechanically, by making use of an appropriate pilot valves to minimize the loss of energy in the course
of flow regulation. The 400X flow control valves can completely stop the flow in case of an emergency
to avoid loss.Accordingly, it boasts high control sensitivity and is reliable, safe, simple to debug and
offers a long service life.Pressure Rating: PN10. PN16. PN25/Class150Size Range: DN20mm-
DN800mm (3/4" - 32")Test and inspection: GB/T 13927 API598 |
The valves limits the flow rate in the pipeline to a preset rate, regardless of upstream pressure variations.
The valves is controlled by pilot valves, which takes use of integrated orifice plate to detect flow rate
represented by differential pressure, and the differential pressure is used to control the pilot valves to
implement flow rate control.
اتصل شخص: Mr. Steve
الهاتف :: +8613818096733
Iron coating EPDM or NBR Resilient seated Gate Valve PN16 600mm
لينة ختم / مقعد مطاطي ويدج مرونة يجلس بوابة صمام كامل تتحمل
لينة الوتد يجلس 10 بوصة بوابة صمام مع المغزل SS316 للمواد الكيميائية
خفيفة الوزن شفة نهاية المرنة يجلس بوابة صمام DIN F4 / Ductile الحديد بوابة الصمامات
أزرق WCB / WC6 يلقي الصلب بوابة صمام لمحطة الطاقة / بعقب اللحام بوابة صمام
شفة مزورة الصلب بوابة صمام درجة الحرارة العالية ، صمام بوابة الخيوط
2 "صمام مأخذ اللحام الفولاذي المصبوب SW / صمام بوابة بونيت الملحومة
1/4'' Perforated Holes Conical Or Basket Type strainer Mounting Between Two Flanges
المصبوب الصلب A216 WCB Y نوع مصفاة مع تصفية SS304 ، JIS 20K شفة النهاية
حديد الدكتايل GGG40 قابل للتعديل مصفاة عداد المياه مع تمديد الأنابيب للرقائق
OEM متر مصفاة المياه DN50 ~ DN200 ، تصفية الحجم 20/40/60/80 شبكة